| AS-i safe connection module |
ASI |
|
| |
|
- Connection for AS-i-Safe Bus for standard safety systems
- Simple and well-arranged cable layout
- Easy storage
- Flexible system - easily expandable
- Simple addressing
- Use of standard safety components
|
|
| |
|
| |
The AS-i Safe connection module is used to connect safety sensors such as safety light curtains, safety light
grids, safety area scanner to an AS-i Safe Bus system. An 8 x 4 Bit code table will be transmitted by the AS-i system
. The code table will be evaluated by the AS-i safe monitor. The safety sensors can be connected directly
by M12 plugs or by use of standard cable on the AS-i Safe connection module |
| |
|
| |
|
| |
Technical data |
| |
| Electrical data |
2 safe inputs (OSSD) |
| upply voltage UB DC |
26,5...31,6 V DC |
| Load current |
≤ 35 mA |
| Inputs |
DC PNP |
| Sensor supply |
ext. 24 V DC PELV |
| Load current |
≤ 2 A |
| Short circuit proofed |
Yes |
| Level High/Low-signal 1 (IEC 61131-2 Typ 2) |
> 11 V / < 5 V |
| Imput current High/Low (IEC 61131-2 Typ 2) |
> 6 / < 2 mA |
| Display |
|
| Power LED |
geen |
| Error LED |
red |
| Function LED |
Yellow |
| Ambient temerature [°C] |
-25...55 |
| Protection class |
IP 67 |
|
| |
dimensions |
| |
|
| |
Download |
|
| |
|
| |
Contact |
|
|

Firma Fiessler Elektronik GmbH & Co. KG
Kastellstr. 9
D-73734 Esslingen
Internet: www.fiessler.de
eMail: info@fiessler.de |
ASI
(0711) 91 96 97 - 13
technical Information
(0711) 91 96 97 - 10
Ordering and price information |
|
| |
|
| |home| |
© 2010 |
| |