ULVT - Grid |
| |
|
|
|
| |
|
|
- Passable areas
- Horizontal safeguarding
- Robotic areas
- Entrance to dangerous areas
|
| |
| |
The light curtain correspond to the following safety regulations. |
| |
|
|
|
IEC 61508 |
ISO 13849-1 |
EN 954-1 |
|
| |
| |
- integrated control-unit with contactor control and restart activatable
by DIP switches activatable
- contactor/valves directly connectablly, switching capacity 0,5A/24V
- 2 to 20 beams at protection heights of 100mm to 1900mm in 100mm steps
- microprocessor monitoring of the safety functions
- built in selfdiagnostic with error display
- muting and stroke operation with optional safety control-unit
- short reaction time
- protective system IP65
- Reach to 24 m/optional till 60 m practicable
|
| |
|
|
| |
|
The safety light curtains ULVT consist of
the two components: transmitter and receiver. The distance between both
components and the overall height result in those protection width and
- height.
By the modular construction protection heights of 100mm to 1900mm are
realizable. Special sizes are also available.
If an object is in the protection field, i.e. it is darkened at least
one of the beams, the two outputs of the receiver interrupt the dangerous
movement of the machine, or prevent a start. A renewed start of the machine
is in the operating mode with restart only possible by pressing the start
push-button during a free protection field.
Several LED at the receiver display thereby the respective operating
condition. The system detects an internal or external error the machine
is immediately switched off and the LED in the transmitter or in the receiver
shows by flashing the error status. |
| |
|
Integrated
connector plug in connector cover |
| |
| The ULVT construction series is supplied with PG threaded
joints as standart. Various conventional connector plugs can also be obtained
as optional accessories. The electric connection is implemented via terminal
screws in the connector cover. The cover can be removed once the 4 screws
have been loosened. |
|
|
|
|
Operating
modes |
| |
| 
DIP-position
Without contactor check |

DIP-position
With contactor check |
The operating mode with contactor control serves for
monitoring the triggered follow-up contactors.
After each interruption of the optical path and before each release
of the switching outputs the follow-up contaction are checked whether
they dropped. If the contactors don´t dropped with in 300ms
the light curtain output contacts go into lock status. |
|
|
|
| 
DIP-position
Without restart interlock |

DIP-position
With restart interlock |
If the operating mode with restart control is adjusted,
a push-button must be connected for the start release of the working
movement.
With a free protection field the yellow LED lights up. After actuating
the start push-button the two outputs of the ULVT are activ. |
|
|
|
| 
DIP-position
Equivalent outputs |

DIP-position
Antivalen outputs |
In the operating mode bivalent outputs both PNP outputs
are errorproof and internally monitored on short circuit ad transverse.
With free optical path, both outputs are high (+24V). In the operating
mode antivalent outputs with free optical path output1 is high (+24V)
and output2 is low (0V). Output2 is not error-proof in this operating
mode. This operating mode is only allowed in connection with the control-units
LSUW N1-Muting K or another safe secondary
control, which monitors the Output2! |
|
| |
|
technical
data |
| |
| |
Transmitter ULVTS |
Receiver ULVTE |
| Supply voltage |
24V DC SELV, +20% -10% |
24V DC SELV, +/- 20% |
| Current consumption |
max. 250mA |
max. 250mA (without load) |
| Outputs |
- |
OSSD 1 and 2:
error-proof PNP outputs; max. 0,5A short-circuit and transverse conclusion
monitoring
(in operating mode of antivalent outputs Output2 is not error-proof,
max. 20mA) |
| Inputs |
- |
Inputs contactor control and start push-button: 0V
to 24V DC + / - 20% |
| electrical link |
integrated plug connector with PG9 as strain relief;
alternatively usual market plug connectors |
integrated plug connector with PG9 as strain relief;
alternatively usual market plug connectors |
| Lead |
3-pol. max 1,5mm² |
5 to 7-pol. (depending upon type of driving) max.
1,5mm² |
|
| |
|
|
|
Executions |
| |
|
|
| |
| |
|
Entrance protection |
Entrance protection |
Entrance protection |
Entrance protection |
Entrance protection |
Entrance protection |
| Protective
field height (mm) |
|
Beam Spacing
100mm
no. of beams
|
Beam Spacing
200mm
no. of beams
|
Beam Spacing
300mm
no. of beams
|
Beam Spacing
400mm
no. of beams
|
Beam Spacing
500mm
no. of beams
|
Beam Spacing
500mm
no. of beams
|
| |
|
|
|
|
|
|
|
| 100 |
196 |
- |
- |
- |
- |
- |
- |
| 200 |
296 |
3 |
2 |
- |
- |
- |
- |
| 300 |
396 |
4 |
- |
2 |
- |
- |
- |
| 400 |
496 |
5 |
3 |
- |
2 |
- |
- |
| 500 |
596 |
6 |
- |
- |
- |
2 |
- |
| 500/2R |
650 |
Beam
diversion via mirror. Wiring required to only one head.
|
- |
2 |
| 600 |
696 |
7 |
4 |
3 |
- |
- |
- |
| 700 |
796 |
8 |
- |
- |
- |
- |
- |
| 800 |
896 |
9 |
5 |
- |
3 |
- |
- |
| 900 |
996 |
10 |
- |
4 |
- |
- |
- |
| 1000 |
1096 |
11 |
6 |
- |
- |
3 |
- |
| 1100 |
1196 |
12 |
- |
- |
- |
- |
- |
| 1200 |
1296 |
13 |
7 |
5 |
4 |
- |
- |
| 1300 |
1396 |
14 |
- |
- |
- |
- |
- |
| 1400 |
1496 |
15 |
8 |
- |
- |
- |
- |
| 1500 |
1596 |
16 |
- |
6 |
- |
4 |
- |
| 1600 |
1696 |
17 |
9 |
- |
5 |
- |
- |
| 1700 |
1796 |
18 |
- |
- |
- |
- |
- |
| 1800 |
1896 |
19 |
10 |
- |
- |
- |
- |
| 1900 |
1996 |
20 |
- |
- |
- |
- |
- |
|
| |
|
Download |
| ULVT |
1500 kB |
Operating instructins/Betriebsanleitung |
english |
|
|
| |
|
|
| |
|
Contact |
|
|
| |

Firma Fiessler Elektronik GmbH & Co. KG
Kastellstr. 9
D-73734 Esslingen
Internet: www.fiessler.de
eMail: info@fiessler.de
|
Guard ULVT
++49(711) 91 96 97 - 27
technical information
++49(711) 91 96 97 - 10