Switchgear and control units
Maximum occupational safety with minimum production interruptions thanks to the precise, intelligent integration of safety sensors into the machine safety circuit. Our reliable switching and control devices are the ideal safety solution for industrial plants, automation and production processes.
FMSC-FP - Foot switch

FMSC-FP
Application
With the FMSC-FP electronic switching device , a second foot switch can be easily and cost-effectively retrofitted to an existing system without having to make significant changes to the existing safety circuit.
Range of functions
- Selection of foot switch operating mode
- Foot switch 1 only
- Foot switch 2 only
- Foot switch 1 OR foot switch 2
- Foot switch 1 AND foot switch 2
- Connection of foot switch 1 and foot switch 2
- Emergency stop function can be retrofitted via foot switch
- Integration into existing safety circuit via relay or directly via electronic outputs
- Diagnostic outputs for:
- Hardware error of the selector switch
- Hardware error of the foot switch
- Relay monitoring errors
Scope of delivery
FMSC-FP electronic switching device including integration proposal
FMSC-STM - Step mats

FMSC-STM
Application
With the FMSC-STM electronic switching device , safety contact mats and emergency stop switches can be retrofitted to an existing system without having to make significant changes to the existing safety circuit. An approval push button can also be installed to bypass a contact mat.
Range of functions
- Connection of:
- 2 safety contact mat circuits
- 1 approval push button
- Emergency stop switches
- 1 acknowledgement button
- Optionally with or without restart interlock
- Integration into existing safety circuit by means of relays or directly via electronic outputs
- Diagnostic output for relay monitoring error
Scope of delivery
FMSC-STM electronic switching device including integration proposal
FMSC-THC - Push button

FMSC-THC
Application
The FMSC-THC electronic switching device can be used to monitor two connected push-buttons.
A two-hand circuit of type III C in accordance with EN 574 can be connected to this device.
The push-buttons each consist of a normally open and normally closed contact. Discrepancy time monitoring of the NO and NC contacts of the individual contacts and between the push-buttons takes place at the inputs.
The two-channel emergency stop and the relay/contactor monitoring can be deselected, allowing the device to be used flexibly.
Range of functions
- Connection of:
- 2 push-buttons, each with a normally open and normally closed contact
- 1 acknowledgement button
- Optionally with or without emergency stop
- Optionally with or without contactor monitoring
- Integration in safety circuit via relay or directly via electronic outputs
- Diagnostic output for
- Relay monitoring error
- Two-hand discrepancy time monitoring error or position error of the EDM
Scope of delivery
Electronic switching device FMSC-THC including integration proposal
FMSC-ESM - Monitoring an axis for standstill

FMSC-ESM
Application
The FMSC-ESM electronic switching device can be used to safely monitor an axis for standstill.
Linear or rotary encoders can be used as sensors. Contactor monitoring and restart interlock can be configured, which makes the device extremely flexible to use. It can be connected directly to frequency converters as well as via contactors. An emergency stop circuit can also be connected to the device.
Range of functions
- Connection of:
- 2 standard TTL encoders (linear or incremental)
- Emergency stop circuit
- 1 acknowledgement button
- Brake for stopping in the event of an error
- Optionally with or without restart interlock
- Optionally with or without contactor monitoring
- Integration in safety circuit via relay or directly via electronic outputs
- Diagnostic output for
- Relay monitoring errors
- Encoder deviations
Scope of delivery
Electronic switching device FMSC-ESM including integration proposal
FMSC-PSDI - 1- or 2-cycle protective operation on light barriers

FMSC-PSDI
Application
The FMSC-PSDI cycle switching device can be used to implement 1-cycle, 2-cycle or protective operation on a light barrier.
The individual operating modes can be selected via a selector switch. If the system is in the Monitor Start Point, the start button must be pressed.
Depending on the selection, the number of interruptions then occurs. The safe outputs sO1 and sO2 are enabled by pressing the start button again.
The relay optionally connected to these outputs is monitored for the switching states.
An input can optionally be used to select whether the interventions are only counted in the Motion Start Point or during the safe movement. An input can also be used to select whether a start is possible after an interruption in all positions or only in the Motion Start Point.
Additional outputs are available for displaying a monitoring error, an interrupt request, a muting signal, the motion start point and for requesting the operation of a start button.
Range of functions
Inputs:
- OSSD1/2 AOPD
- Operating mode selector switch
- Restart/start/PSDI start button
Outputs:
- 2 safe outputs
- 24V AOPD
Signal outputs:
- Restart
- PSDI Start
- Motion Start Point
- Interruption necessary
- Error
Optional:
- Contactor monitoring
- Break Count Position only in Motion Start Point
- Start at all positions
Scope of delivery
Electronic switching device FMSC-PSDI including integration proposal
PLSG - Muting control unit




PLSG safety control unit
The PLSG series switchgear saves costs thanks to
- Direct on-site wiring thanks to plug-in technology
Short cable runs Reduction in installation costs Saving of switch cabinet space Integrated muting lamp - Direct connection of safety components
No need for safety switching devices for emergency stop, safety gate switch, two-hand control panel or cycle controls - Minimum parameterization effort
No software required Short commissioning times Fastest replacement in the event of a fault
The muting function enables personnel protection with unhindered material flow
- Access guarding for automatic production systems
- Protection of access openings to production cells
- Protection of palletizing systems
- Conveyor and storage technology
ULSG - Power supply for light curtains

ULSG
The ULSG switching device provides potential-free output contacts and a universal power supply (optionally 230 V AC, 115 V AC or 24 V DC connection). The ULSG switching device fulfills the power failure bridging of 20 ms required by EN 60204 and is therefore suitable as a power supply for the ULVT / BLVT / TLVT / ILVT, ULCT / BLCT / TLCT / ILCT light curtains and FLSC area scanners.
- Universal power supply for light curtains
- Connection of 24 VDC, 115 VAC or 230 VAC possible
- Potential-free output contacts
- Connection for 2 to 6 light curtains
- Simple series connection with additional safety sensors
- Connection to standard safety bus nodes possible
- Cost-effective solution if 24 VDC is not available
- high switching capacity - top-hat rail mounting
BLPG - Blanking programmer

BLPG - Blanking programmer
Programming is carried out by pressing a key switch. The programming device is not absolutely necessary for operating the light grid and can be removed again once programming is complete. Teach-in of the beam blanking functions with BLPG via external key switch (BLVT programming device) for PLSG2/PLSG3 Save and recall up to 5 operating modes in PLSG3 Save and recall up to 5 operating modes in PLSG3 and simultaneously up to 5 beam blanking modes in BLVT light grid
BPSG - Blanking programmer with power supply

BPSG - Blanking programmer with power supply
Blanking programmer and switching device like type BLPG, but with additional power supply and force-guided relay with potential-free outputs.
- Simple programming of blanking light curtains
- Connection of 24 VDC, 115 VAC or 230 VAC possible
- potential-free output contacts - top hat rail mounting
- Selector switch operation
- Device can be removed after programming
- Blanking program is stored directly in the receiver
- No PC required for programming
- Desired blanking type can be set via DIP switch
AMS 3 - AKAS Muting system

AMS 3
The AMS 3 muting system generates the control and muting signals required for AKAS®-F in accordance with safety category 4 or PLe. Two magnetic tape sensors are connected to the AMS 3 to record information about the direction of movement and speed. One sensor for the Y1 axis and one sensor for Y2. In addition, the AMS 3 can perform the overtravel measurement in rapid traverse.
LSUW N1 Muting K - switching device

LSUW N1 Muting K
In addition to the power supply, the LSUW N1 Muting K switching device contains all the switching elements required for the safe activation of power-driven work equipment or for activating an alarm. This considerably reduces the additional switching work that is otherwise often required.
The following function groups are integrated as standard
- Control for the light barrier transmitter
- Monitoring of the light barrier
- Start and restart interlock and monitoring of valves or contactors
- Two potential-free, monitored NO contacts for controlling the downstream machine
- Activation and monitoring of the muting sensors
- Monitoring of the muting lamp
- Integrated bridging function (muting)
- Programmable muting function with or without time monitoring