The MLVT light curtain system from Fiessler Elektronik is a measuring light curtain for precise industrial measurement and control tasks. It consists of a transmitter and a receiver strip that generate a finely resolved measuring field. Within this field, the system not only detects whether an object is present, but also measures its position, size and shape - ideal for applications in object measurement, quality control or process monitoring. Its great advantage lies in its high measuring accuracy and repeatability combined with a robust, industrial design. The MLVT system therefore delivers reliable data even during fast production processes, ensuring maximum efficiency and quality in modern manufacturing processes.
Typical applications include
Painting systems - Control of spray guns
Conveyor belts - sorting boxes by size
Classification of trees
Function
How MLVT works
A large number of light beams at a distance of 7.5mm or 14mm are controlled by a single-chip microcontroller. All eyes are scanned one after the other. This allows the status of all eyes to be determined. This data can be further processed as required via a serial interface.
Properties
No geometric measurement error due to parallel measurement
Fast detection time from 1.2 ms to 10.3 ms, depending on the overall length
Smallest scanning grid of 7.5 mm
Protection class IP 65
Sensor field heights from 100 mm to 1900 mm available in 100 mm increments
Range 7 m
Small contactor / valves can be connected directly
Universal mounting thanks to sliding sliding blocks
2 short-circuit-proof antivalent semiconductor outputs PNP, switching behavior 0.5 A / 24 V
Serial interface (RS 485) for IPC or PLC (optional interface converter)
Technical data
Supply voltages:
24V DC ±20%, stabilized; max. 200 mA
Connection:
integrated plug connector with PG9 as strain relief, alternatively commercially available plug connectors
Ambient temperature:
-10 °C to 50 °C
Outputs:
PNP; output FREI and output interrupted; max. 500mA (short-circuit proof) RS-485 interface (9600,N,8,1) Optional converter to Profibus-DP fieldbus/RS 232