Safety Light curtains ILCT

Properties

  • Integrated control-unit with contactor control and restart can be programmed without a PC
  • Contactor/valves directly connectablly, switching capacity 0,5A/24V
  • Smallest safety distances by short response times 4 ms to 29 ms, depending of the protection high
  • Finger and hand protection with up to 5m protective width(resolution 14 mm and 30 mm)
  • Protection heights from 100mm to 1500 mm in steps of 100 mm
  • Microcontroller monitoring of the safety functions (self-monitored)
  • Semiconductor outputs with short-circuit and crossconnection monitoring
  • Integrated self-diagnosis with a fault indication by 7-digit display
  • Optional safety switchgears permit muting and clocked operation
  • Direct connection via M12 connector
  • Compact design 25 x 35 mm w/ flexible fastening by tenon blocks and protection category IP 65

The light curtain correspond to the following safety regulations:
Safety Integrity Level SIL 1 (IEC 61508) 
Performance Level PL e (ISO 13849-1)
Safety category cat. 2 (EN 954-1)

Function description

Assembly

Operating mode

ULCTBLCTTLCTILCT 
++++Finger protection(resolution14 mm)
+-+-Hand protection(resolution 30 mm)
++++EDM - Contactor control
++++RES - restart interlock
++++Cascaded
-+-+Blanking
-+-+Reduced resolution
with a Muting controller PLSK1K - PLSG3K or Programmable Safety Center FPSCMuting
with a voltage supply ULSG(potential free Outputs) or Contact extension FSEMRelay output optional

with a controller PLSG3K or Programmable Safety Center FPSC
Cyclical control 1 - 4 cycl
Emergency-stop circuit monitor
Door switch monitoring

Technical data

 Transmitter ILCT - SReceiver TLCT - E / ILCT - E
Supply voltage24 V DC + 20 % - 15 % SELV, PELV24 V DC ± 20% SELV, PELV
Current consumptionmax. 250mAmax. 250 mA (without load)
Outputs-OSSD 1 and 2: Fail-safe PNP outputs with short-circuit and
cross-connection monitoring.
Output current: min. 0 mA: max. 0.5 A
Max. output current in the inactive state: 50 μA
Max. voltage in the inactive state: 0.9 V
Max. capacitive load: 1 μF
Inputs-Contactor control (EDM) and start button
0 V to 24 V DC ± 20 %, max. 5 mA
Electrical connectionM12 plug connector, 4-poleM12 plug connector, 8-pole

Implementation

ULCT / 14 mm resolution(finger protection)
System: 
Protective field height/Beam count
Reaction time (ms)Length (mm)
ILCT 100/125161
ILCT 200/246261
ILCT 300/367361
ILCT 400/488461
ILCT 500/609561
ILCT 600/7210661
ILCT 700/8411761
ILCT 800/9612861
ILCT 900/10813961
ILCT 1000/120141061
ILCT 1100/132151161
ILCT 1200/144171261
ILCT 1300/156181361
ILCT 1400/168191461
ILCT 1500/180201561

Downloads

ProductDocumentation
BLPG/BPSGOperating Instructions: Programming devices for ILCTPDFPDF------
ILCTSelection table LightcurtainPDF-------
ILCTAppliance descritionPDFPDFPDFPDF----
ILCTOperating InstructionsPDFPDF------
ILCT 100 - 1500Housing design / CAD formats stp,igs,dxf,dwgPDF
SISTEMA BibliothekFiessler Sistema LibrarySISTEMA Bibliothek

Contact