Safety Light curtains TLCT

Properties

  • Integrated control-unit with contactor control and restart can be programmed without a PC
  • Contactor/valves directly connectablly, switching capacity 0,5A/24V
  • Smallest safety distances by short response times 4 ms to 29 ms, depending of the protection high
  • Finger and hand protection with up to 5m protective width(resolution 14 mm and 30 mm)
  • Protection heights from 100mm to 1500 mm in steps of 100 mm
  • Microcontroller monitoring of the safety functions (self-monitored)
  • Semiconductor outputs with short-circuit and crossconnection monitoring
  • Integrated self-diagnosis with a fault indication by 7-digit display
  • Optional safety switchgears permit muting and clocked operation
  • Direct connection via M12 connector
  • Compact design 25 x 35 mm w/ flexible fastening by tenon blocks and protection category IP 65

The light curtain correspond to the highest safety regulations:
Safety Integrity Level SIL 1 (IEC 61508) 
Performance Level PL c (ISO 13849-1)
Safety category cat. 2 (EN 954-1)

Function description

Assembly

Operating mode

ULCTBLCTTLCTILCT 
++++Finger protection(resolution14 mm)
+-+-Hand protection(resolution 30 mm)
++++EDM - Contactor control
++++RES - restart interlock
++++Cascaded(variant......K)
-+-+Blanking
-+-+Reduced resolution
with a Muting controller PLSK1K - PLSG3K or Programmable Safety Center FPSCMuting
with a voltage supply ULSG(potential free Outputs) or Contact extension FSEMRelay output optional

with a controller PLSG3K or Programmable Safety Center FPSC
Cyclical control 1 - 4 cycl
Emergency-stop circuit monitor
Door switch monitoring

Technical data

 Transmitter TLCT - SReceiver TLCT - E / ILCT - E
Supply voltage24 V DC + 20 % - 15 % SELV, PELV24 V DC ± 20% SELV, PELV
Current consumptionmax. 250mAmax. 250 mA (without load)
Outputs-OSSD 1 and 2: Fail-safe PNP outputs with short-circuit and
cross-connection monitoring.
Output current: min. 0 mA: max. 0.5 A
Max. output current in the inactive state: 50 μA
Max. voltage in the inactive state: 0.9 V
Max. capacitive load: 1 μF
Inputs-Contactor control (EDM) and start button
0 V to 24 V DC ± 20 %, max. 5 mA
Electrical connectionM12 plug connector, 4-poleM12 plug connector, 8-pole

Implementation

TLCT / 14 mm resolution(finger protection)TLCT / 30 mm resolution(hand protection)
System: 
Protective field height / Beam count
Reaction time (ms)Length (mm)System: 
Protective field height / Beam count
Reaction time (ms)Length (mm)
TLCT 100/125161TLCT 100/44161
TLCT 200/246261TLCT 200/85261
TLCT 300/367361TLCT 300/125361
TLCT 400/488461TLCT 400/166461
TLCT 500/609561TLCT 500/206561
TLCT 600/7210661TLCT 600/247661
TLCT 700/8411761TLCT 700/287761
TLCT 800/9612861TLCT 800/327861
TLCT 900/10813961TLCT 900/368961
TLCT 1000/120141061TLCT 1000/4081061
TLCT 1100/132151161TLCT 1100/4481161
TLCT 1200/144171261TLCT 1200/4891261
TLCT 1300/156181361TLCT 1300/5291361
TLCT 1400/168191461TLCT 1400/56101461
TLCT 1500/180201561TLCT 1500/60101561

Downloads

ProductDocumentation
TLCTSelection table LightcurtainPDF-------
TLCTAppliance descritionPDFPDFPDFPDF----
TLCTOperating InstructionsPDFPDF------
TLCT 100 - 1500Housing design / CAD formats stp,igs,dxf,dwgZIP
SISTEMA BibliothekFiessler Sistema LibrarySISTEMA Bibliothek

Contact

Safety light curtain - TLCT

(0711) 91 96 97 - 27 
technical information

(0711) 91 96 97 - 10
Ordering and price information