Safety Light curtains ULCT

Properties

  • Integrated control-unit with contactor control and restart can be programmed without a PC
  • Contactor/valves directly connectablly, switching capacity 0,5A/24V
  • Smallest safety distances by short response times 4 ms to 29 ms, depending of the protection high
  • Finger and hand protection with up to 5m protective width(resolution 14 mm and 30 mm)
  • Protection heights from 100mm to 1500 mm in steps of 100 mm
  • Microcontroller monitoring of the safety functions (self-monitored)
  • Semiconductor outputs with short-circuit and crossconnection monitoring
  • Integrated self-diagnosis with a fault indication by 7-digit display
  • Optional safety switchgears permit muting and clocked operation
  • Direct connection via M12 connector
  • Compact design 25 x 35 mm w/ flexible fastening by tenon blocks and protection category IP 65

The light curtain correspond to the following safety regulations:
Safety Integrity Level SIL 3 (IEC 61508) 
Performance Level PL e (ISO 13849-1)
Safety category cat. 4 (EN 954-1)

Function description

Assembly

Operating mode

ULCTBLCTTLCTILCT 
++++Finger protection(resolution14 mm)
+-+-Hand protection(resolution 30 mm)
++++EDM - Contactor control
++++RES - restart interlock
++++Cascaded(variant......K)
-+-+Blanking
-+-+Reduced resolution
with a Muting controller PLSK1K - PLSG3K or Programmable Safety Center FPSCMuting
with a voltage supply ULSG(potential free Outputs) or Contact extension FSEMRelay output optional

with a controller PLSG3K or Programmable Safety Center FPSC
Cyclical control 1 - 4 cycl
Emergency-stop circuit monitor

Technical data

 Transmitter ULCT - SReceiver ULCT - E / BLCT - E
Supply voltage24 V DC + 20 % - 15 % SELV, PELV24 V DC ± 20% SELV, PELV
Current consumptionmax. 250mAmax. 250 mA (without load)
Outputs-OSSD 1 and 2: Fail-safe PNP outputs with short-circuit and
cross-connection monitoring.
Output current: min. 0 mA: max. 0.5 A
Max. output current in the inactive state: 50
μA
Max. voltage in the inactive state: 0.9 V
Max. capacitive load: 1
μF
Inputs-Contactor control (EDM) and start button
0 V to 24 V DC ± 20 %, max. 5 mA
Electrical connectionM12 plug connector, 4-poleM12 plug connector, 8-pole

Implementation

ULCT / 14 mm resolution(finger protection)ULCT / 30 mm resolution(hand protection)
System: 
Protective field height/Beam count
Reaction time (ms)Length (mm)System: 
Protective field height/Beam count
Reaction time (ms)Length (mm)
ULCT 100/125161ULCT 100/44161
ULCT 200/246261ULCT 200/85261
ULCT 300/367361ULCT 300/125361
ULCT 400/488461ULCT 400/166461
ULCT 500/609561ULCT 500/206561
ULCT 600/7210661ULCT 600/247661
ULCT 700/8411761ULCT 700/287761
ULCT 800/9612861ULCT 800/327861
ULCT 900/10813961ULCT 900/368961
ULCT 1000/120141061ULCT 1000/4081061
ULCT 1100/132151161ULCT 1100/4481161
ULCT 1200/144171261ULCT 1200/4891261
ULCT 1300/156181361ULCT 1300/5291361
ULCT 1400/168191461ULCT 1400/56101461
ULCT 1500/180201561ULCT 1500/60101561

Accessories

Downloads

ProductnameDocumentation
ULCTSelection table LightcurtainPDF-------
ULCTAppliance descritionPDFPDFPDFPDF----