Safety foot-switch, single pedal
Safety foot pedal FE-FS1-SU1ASDU1-U-XX
The foot pedal FE-FS1-SU1ASDU1-U have 3 positions with a pressure point, to control dangerous movements (for instance get down of a press brake ect ). It has 2 working contacts ( 1NC+1NO) to drive the movement and one safety switches (1 positive opening NC contact + 1NO) to stop the movement. Pressing the foot pedal, till the pressure point, allows the changeover of the 2 working contacts. Once the pressure point is got over, the 2 working contacts return to their first position and the positive opening safety contact is activated in order to initiate immediately the dangerous movement. Thus a redundant information for the safety circuit is available.
A restart of the machine is only possible after releasing the foot switch.
Safety foot pedal FE-FS1-SU1ASDO2-U-XX
The foot pedal FE-FS1-SU1ASDO2-U have 3 positions with a pressure point to control dangerous movements (for instance get down of a press brake ect ). It has 2 working contacts (1NO and 1NC) to drive the movement and one safety switches (2 positive opening NC contacts) to stop the movement.
Pressing the foot pedal, till the pressure point, allows the changeover of the 2 working contacts. Once the pressure point is got over, the 2 working contacts return to their first position and the positive opening safety contact is activated in order to initiate immediately the dangerous movement.
Thus a redundant information for the safety circuit is available.
A restart of the machine is only possible after releasing the foot switch.
Safety foot pedal FE-FS1-SU1ASDO2V-U-XX
The foot pedal FE-FS1-SU1ASDO2V-U have 3 positions with a pressure point and a pedal lock with manual re- lease, to control dangerous movements (for instance get down of a press brake ect ). It has 2 working contacts (1NO and 1NC) to drive the movement and one safety switches (2 positive opening NC contacts)
to stop the movement.
Pressing the foot pedal, till the pressure point, allows the changeover of the 2 working contacts. Once the pressure point is got over, the 2 working contacts return to their first position and the positive opening safety contact is activated in order to initiate immediately the dangerous movement.
Thus a redundant information for the safety circuit is available.
A restart of the machine is only possible after releasing the foot switch.
Safety foot pedal FE-FS1-S2DO2V-U-XX
The foot pedal FE-FS1-S2DO2V-U have 3 positions with a pressure point and a pedal lock with manual release, to control dangerous movements (for instance get down of a press brake ect ). It has 2 working contacts (2NO) to drive the movement and one safety switches (2 positive opening NC contacts) to stop the movement. Pressing the foot pedal, till the pressure point, allows the changeover of the 2 working contacts. Once the pressure point is got over, the 2 working contacts return to their first position and the positive opening safety contact is activated in order to initiate immediately the dangerous movement.
Thus a redundant information for the safety circuit is available.
A restart of the machine is only possible after releasing the foot switch.
Safety foot-switch, double pedal
Safety foot pedal FE-FS2-SU1ASDU1/U1-U-XX
The safety foot pedal FE-FS2-SU1ASDU1/U1-U use safety switches. The right foot pedal have two positions (free position and pressed down position). It may e.g. be used for the selection of AKAS® Box bending function or opening of a press. The left foot pedal have 3 positions, with a pressure point, to control dangerous movements (for instance get down of a press brake ect). It has 2 working contacts ( 1NC+1NO) to drive the movement and one safety switch (1 positive opening NC contact + 1NO) to stop the movement. Pressing the foot pedal, till the pressure point, allows the changeover of the 2 working contacts. Once the pressure point is got over, the 2 working contacts return to their first position and the positive opening safety contact is activated in order to initiate immediately the dangerous movement.Thus a redundant information for the safety circuit is available. A restart of the machine is only possible after releasing the foot switch.
Safety foot pedal FE-FS2-U1/SU1ASDU1-U-XX
The safety foot pedal FE-FS2-U1/SU1ASDU1-U use safety switches. The left foot pedal have two positions (free position and pressed down position). It may e.g. be used for the selection of AKAS® Box bending function or opening of a press. The right foot pedal have 3 positions, with a pressure point, to control dangerous movements (for instance get down of a press brake ect). It has 2 working contacts ( 1NC+1NO) to drive the movement and one safety switch (1 positive opening NC contact + 1NO) to stop the movement. Pressing the foot pedal, till the pressure point, allows the changeover of the 2 working contacts. Once the pressure point is got over, the 2 working contacts return to their first position and the positive opening safety contact is activated in order to initiate immediately the dangerous movement.Thus a redundant information for the safety circuit is available. A restart of the machine is only possible after releasing the foot switch.
Safety foot pedal FE-FS2-S2ASDO2/U1-U-XX
The safety foot pedal FE-FS2-S2ASDO2/U1-U use safety switches. The right foot pedal have two positions (free position and pressed down position). It may e.g. be used for the selection of AKAS® Box bending function or opening of a press. The left foot pedal have 3 positions, with a pressure point, to control dangerous movements (for instance get down of a press brake ect). It has 2 working contacts ( 2NO) to drive the movement and one safety switch (2 positive opening NC contact ) to stop the movement. Pressing the foot pedal, till the pressure point, allows the changeover of the 2 working contacts. Once the pressure point is got over, the 2 working contacts return to their first position and the positive opening safety contact is activated in order to initiate immediately the dangerous movement.Thus a redundant information for the safety circuit is available. A restart of the machine is only possible after releasing the foot switch.
Safety foot pedal FE-FS2-SU1ASDO2/U1-U-XX
The safety foot pedal FE-FS2-SU1ASDO2/U1-U use safety switches.
The right foot pedal have two positions (free position and pressed down position). It may e.g. be used for the selection of AKAS® Box bending function or opening of a press. The left foot pedal have 3 positions, with a pressure point, to control dangerous movements (for instance get down of a press brake ect ). It has 2 working contacts ( 1NC+1NO) to drive the movement and one safety switch (2 positive opening NC contacts) to stop the movement. Pressing the foot pedal, till the pressure point, allows the
changeover of the 2 working contacts. Once the pressure point is got over, the 2 working contacts return to their first position and the positive opening safety contact is activated in order to initiate immediately the dangerous movement.Thus a redundant information for the safety circuit is available.
A restart of the machine is only possible after releasing the foot switch.
Safety foot pedal FE-FS2-U1/SU1ASDO2S-U-XX
The safety foot pedal FE-FS2-U1/SU1ASDO2S-U use safety switches and a lever.
The left foot pedal have two positions (free position and pressed down position). It may e.g. be used for the selection of AKAS® Box bending function or opening of a press. The right foot pedal have 3
positions, with a pressure point, to control dangerous movements (for instance get down of a press brake ect ). It has 2 working contacts ( 1NC+1NO) to drive the movement and one safety switch (1 positive opening NC contact + 1NO) to stop the movement. Pressing the foot pedal, till the pressure point, allows the changeover of the 2 working contacts. Once the pressure point is got over, the 2 working contacts return to their first position and the positive opening safety contact is activated in order to initiate immediately the dangerous movement.Thus a redundant information for the safety circuit is available.
A restart of the machine is only possible after releasing the foot switch.
Safety foot pedal FE-FS2-SU1ASDO2/SU1ASDO2-U-XX
The safety foot pedal FE-FS2-SU1ASDO2/SU1ASDO2-U use safety switches.
The two foot pedals have 3 positions, with a pressure point, to control dangerous movements (for instance get down of a press brake ect ). Each pedal has 2 working contacts ( 1NC+1NO) to drive the movement and one safety switch (2 positive opening NC contacts) to stop the movement. Pressing the foot pedal, till the pressure point, allows the changeover of the 2 working contacts. Once the pressure point is got over, the 2 working contacts return to their first position and the positive opening safety contact is activated in order to initiate immediately the dangerous movement. Thus a redundant information for the safety circuit is available. A restart of the machine is only possible after releasing the foot switch.
Safety foot pedal FE-FS2-SU1ASDU1/SU1ASDU1-U-XX
The safety foot pedal FE-FS2-SU1ASDU1/SU1ASDU1-U use safety switches.
The two foot pedals have 3 positions, with a pressure point, to control dangerous movements (for instance get down of a press brake ect ). Each pedal has 2 working contacts ( 1NC+1NO) to drive the movement and one safety switch (1 positive opening NC contact and 1 NO contact) to stop the movement.
Pressing the foot pedal, till the pressure point, allows the changeover of the 2 working contacts. Once the pressure point is got over, the 2 working contacts return to their first position and the positive opening safety contact is activated in order to initiate immediately the dangerous movement. Thus a redundant information for the safety circuit is available. A restart of the machine is only possible after releasing the foot switch.
Safety foot pedal FE-FS2-U1/SU1ASDO2-U-XX
The safety foot pedal FE-FS2-U1/SU1ASDO2-U use safety switches.
The left foot pedal have two positions (free position and pressed down position). It may e.g. be used for the selection of AKAS® Box bending function or opening of a press. The right foot pedal have 3 positions, with a pressure point, to control dangerous movements (for instance get down of a press brake ect ). It has 2 working contacts (1NC+1NO) to drive the movement and one safety switch (2 positive opening NC contacts) to stop the movement. Pressing the foot pedal, till the pressure point, allows the
changeover of the 2 working contacts. Once the pressure point is got over, the 2 working contacts return to their first position and the positive opening safety contact is activated in order to initiate immediately the dangerous movement.Thus a redundant information for the safety circuit is available.
A restart of the machine is only possible after releasing the foot switch.
Safety foot pedal FE-FS2-U2/SU2ASDU1-U-XX
The safety foot pedal FE-FS2-U2/SU2ASDU1-U use safety switches.
The left foot pedal have two positions (free position and pressed down position). It may e.g. be used for the selection of AKAS® Box bending function or opening of a press. The right foot pedal have 3
positions, with a pressure point, to control dangerous movements (for instance get down of a press brake ect ). It has 2 working contacts ( 1NC+1NO) to drive the movement and one safety switch (1 positive opening NC contact + 1NO) to stop the movement. Pressing the foot pedal, till the pressure point, allows the changeover of the 2 working contacts. Once the pressure point is got over, the 2 working contacts return to their first position and the positive opening safety contact is activated in order to initiate immediately the dangerous movement.Thus a redundant information for the safety circuit is available.
A restart of the machine is only possible after releasing the foot switch.
Foot-switch, single pedal
Foot pedal FE-FS1-U1-U-XX
The foot pedal FE-FS1-U1-U is equipped with a switching element, which contains one NC and one NO contact. It may e.g. be used for the selection of AKAS® Box bending function or opening of a press.
Foot pedal FE-FS1-U1-U-XX
The foot pedal FE-FS1-U1-U use one switch.
It has 2 working contacts (1NC+ 1NO) to drive the movement.
Foot pedal FE-FS1-SU1P10K-U-XX
The foot pedal FE-FS1-SU1P10K-U is equipped with a change-over contact with potentiometer. It may e.g. be used for continuous control tasks.
Foot-switch, double pedal
Technical data
Operating voltage | max. 500 VAC, 40-60Hz |
Switching current | max. 10 A. For inductive and capacitive loads, a contact protection must be provided. |
Operations | min. 10 Mio. |
Contact Material | Silver |
Connection type | Screwterminal |
Electrical connection | 0,5-1,5 mm2 |
Housing | Die cast aluminum, powder-coated RAL 7021 (dark gray) |
Pedal | Die cast aluminum, powder-coated RAL 7021 (dark gray) |
Accident cover | Die cast aluminum, powder-coated |
Attachment | For mounting of the footpedal in the housing bottom (pedal area) are provided 2xØ4,5 and 2xØ6,5 holes (see drawing) |
Protection type | IP65 to IEC/EN 60529 |
Operating temperature | -30°C to +80°C |
Regulations | IEC/EN 60204 , IEC/EN 60947-5-1 |
Downloads
Product name | Documentation | ||||||||
---|---|---|---|---|---|---|---|---|---|
- | Overview foot-pedals & Safety foot-pedals | - | - | - | - | - | - | ||
Safety foot-switch, single pedal | |||||||||
FE-FS1-SU1ASDU1-U | appliance description | - | - | - | - | - | - | ||
FE-FS1-SU1ASDO2-U | appliance description | - | - | - | - | - | - | ||
FE-FS1-SU1ASDO2V-U | appliance description | - | - | - | - | - | - | ||
FE-FS1-S2DO2V-U | appliance description | - | - | - | - | - | - | ||
Safety foot-switch, double pedal | |||||||||
FE-FS2-SU1ASDU1/U1-U | appliance description | - | - | - | - | - | - | ||
FE-FS2-U1/SU1ASDU1-U | appliance description | - | - | - | - | - | - | ||
FE-FS2-S2ASDO2/U1-U | appliance description | - | - | - | - | - | - | ||
FE-FS2-SU1ASDO2/U1-U | appliance description | - | - | - | - | - | - | ||
FE-FS2-U1/SU1ASDO2S-U | appliance description | - | - | - | - | - | - | ||
FE-FS2-SU1ASDO2/SU1ASDO2-U | appliance description | - | - | - | - | - | - | ||
FE-FS2-SU1ASDU1/SU1ASDU1-U | appliance description | - | - | - | - | - | - | ||
FE-FS2-U1/SU1ASDO2-U | appliance description | - | - | - | - | - | - | ||
FE-FS2-U2/SU2ASDU1-U | appliance description | - | - | - | - | - | - | ||
Foot-switch, single pedal | |||||||||
FE-FS1-U1-U-YE | appliance description | - | - | - | - | - | - | ||
FE-FS1-U1-U | appliance description | - | - | - | - | - | - | ||
FE-FS1-SU1P10K-U | appliance description | - | - | - | - | - | - | ||
Foot-switch, double pedal | |||||||||
FE-FS2-U1/U1-U | appliance description | - | - | - | - | - | - |
Contact
Firma Fiessler Elektronik GmbH & Co. KG
Buchenteich 14
D-73773 Aichwald
Internet: www.fiessler.de
eMail: info@fiessler.de